Matrix-assisted laser desorption ionization-time of flight mass spectrometry is a sensitive and specific method for identification of aerococci

J Clin Microbiol. 2013 Apr;51(4):1303-4. doi: 10.1128/JCM.02637-12. Epub 2013 Feb 6.

Abstract

Conventional methods for the identification of human-pathogenic aerococci to the species level are not reliable. We show that matrix-assisted laser desorption ionization-time of flight mass spectrometry correctly identifies aerococci to the species level and that it can be used to identify aerococci with high specificity in the diagnostic clinical microbiology laboratory.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aerococcus / chemistry*
  • Aerococcus / classification*
  • Aerococcus / isolation & purification
  • Bacteriological Techniques / methods*
  • Gram-Positive Bacterial Infections / diagnosis
  • Gram-Positive Bacterial Infections / microbiology
  • Humans
  • Sensitivity and Specificity
  • Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization / methods*